Emerson 400508-02 Error The Selection variable can only be assigned a Selection value

Models: 400508-02

1 60
Download 60 pages 56.07 Kb
Page 38
Image 38
Error: The Selection variable can only be assigned a Selection value.

FM-3 Programming Module Installation Manual

Error: The Selection variable can only be assigned a Selection value.

The destination variable only accepts selection values. Selection values are fixed unquoted text. The selection text must exactly match the available selections of the Destination variable.

Error: This instance does not exist.

This variable is referencing an instance that has not been created in your application. For example “Index.9.vel” the instance 9 of index has not been defined.

Error: This is not a fully qualified variable.

To use a variable it must be fully defined. Some variables are global variables and only the name is defined. Other Variables require a name.name convention. Other variables require an instance number (index.1.vel). All the components identifying the variable must be available to qualify the variable.

Error: This variable cannot be assigned a selection value

The variable that you are attempting to define with a selection does not accept selection values.

Error: This variable type cannot be assigned a value

The Variable is of a type that does not accept any assignments. A Source Event variable is an example. You can not assign a value to an output event.

Error: The selection is not valid for this variable

The variable that you are attempting to define with a selection does accept selection values. However the selection you are attempting to use is not accepted by this variable.

Error: Trying to assign a selection variable with bad selection data

When checking to see if the selection goes with the destination variable, the source is not a defined selection for the destination variable.

26

Page 38
Image 38
Emerson 400508-02 Error The Selection variable can only be assigned a Selection value, Error This instance does not exist