Segment Display
Fault
All "On"
Action to Reset
Normally on for one second during power up
Bridge Disabled
Yes
** Fault **
***** Depend on Fault
Fault Descriptions
Flash Invalid
This fault indicates that the firmware checksum has failed. Use the Tools Program Flash menu item from Emerson Motion Control PowerTools® to reprogram/upgrade the firmware stored in flash memory. If this problem persists, call EMERSON Motion Control. A common cause would be an interrupted F/W Flash upgrade (cable disconnected during an upgrade process).
Watchdog Timer
The watchdog timer ensures that the firmware is operating normally. If the firmware fails to reset this timer every 10 ms, the drive hardware will be reset, all inputs and outputs will be cleared (“Off”), and a Watchdog Timer fault is generated.
Power Up Test
This fault indicates that the
NVM Invalid
At
FM-3 Fault
A 3 will be displayed in the segment display on the E Series drive when the
12