Rosemount 708

Reference Manual

00809-0100-4708, Rev AD September 2012

Hazardous Locations Certificates

North American Certifications

Factory Mutual (FM) Approvals

I5 Intrinsically Safe

Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D Zone Marking: Class I, Zone 0, AEx ia llC

Temperature Codes T4 (Tamb = -40 to 70 °C) Ambient temperature limits: -40 to 70 °C

For use with SmartPower Solutions, model number 701PGN green power module only.

Enclosure Type 4X / IP66/67

Special Conditions for Safe Use (X):

1.The Rosemount 708 Wireless Acoustic Transmitter shall only be used with the SmartPower Solutions, model number 701PGN green power module.

2.Potential Electrostatic charging Hazard – See Instructions.

Standards:

FM3600:1998

FM3610:2010

ANSI/NEMA 250

ANSI/IEC60529:2004

CSA International

I6 CSA Intrinsically Safe Certificate No: 2439890

Applicable Standards: CSA std. C22.2 no. 142-M1987, CSA Std. C22.2 No. 157-92

Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D

T3C (-40 °CTamb 70 °C)

Intrinsically safe when installed according to Rosemount Drawing 00708-1001

For use with SmartPower Solutions, model number 701PGN green power module only.

Enclosure Type 4X, IP66/67

European Certifications

I1 ATEX Intrinsic Safety

Certificate No.: BASEEFA11ATEX0174X II 1G Ex ia IIC T4 (Ta = -40 °C Tamb 70 °C) IP66/67

For use with SmartPower Solutions, model number 701PGN green power module only.

1180

Special Conditions for Safe Use (X):

1.The engineered polymer enclosure of the Rosemount 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.

Standards:

EN60079-0:2009

EN60079-11:2007

B-2