Rosemount 708
Reference Manual
Hazardous Locations Certificates
North American Certifications
Factory Mutual (FM) Approvals
I5 Intrinsically Safe
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D Zone Marking: Class I, Zone 0, AEx ia llC
Temperature Codes T4 (Tamb =
For use with SmartPower Solutions, model number 701PGN green power module only.
Enclosure Type 4X / IP66/67
Special Conditions for Safe Use (X):
1.The Rosemount 708 Wireless Acoustic Transmitter shall only be used with the SmartPower Solutions, model number 701PGN green power module.
2.Potential Electrostatic charging Hazard – See Instructions.
Standards:
FM3600:1998
FM3610:2010
ANSI/NEMA 250
ANSI/IEC60529:2004
CSA International
I6 CSA Intrinsically Safe Certificate No: 2439890
Applicable Standards: CSA std. C22.2 no.
Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D
T3C
Intrinsically safe when installed according to Rosemount Drawing
For use with SmartPower Solutions, model number 701PGN green power module only.
Enclosure Type 4X, IP66/67
European Certifications
I1 ATEX Intrinsic Safety
Certificate No.: BASEEFA11ATEX0174X II 1G Ex ia IIC T4 (Ta =
For use with SmartPower Solutions, model number 701PGN green power module only.
1180
Special Conditions for Safe Use (X):
1.The engineered polymer enclosure of the Rosemount 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth.
Standards: