!WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1.Read your owner’s manual carefully and keep it for future reference.

2.Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, secure- ly fasten a warning device, such as a tag, to the service panel.

3.Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.

4.Do not put anything into the fan blades while they are turning.

5.Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation

1.To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.

2.The installation is to be in accordance with the National Electrical Code, “ANSI/NFPA 70-1999” and Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4.The longer downrod furnished with the fan provides the minimum recommended floor to fan blade clearance for a 9 foot ceiling. The shorter downrod must be used for an 8 foot ceiling.

5.The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.

6.Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know enough about electrical wiring, have your fan installed by a licensed electrician.

NOTE: This fan is suitable for use with solid-state speed controls.

WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed control Model No. UC7067RC, manufactured by Rhine Electric Co., Ltd.

WARNING: This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Electric Co. Substitution of parts or accessories not designated for use with this product by Emerson Electric Co. could result in personal injury or property damage.

WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall control/switch.

DATE CODE:

The date code of this fan may be found on the box, stamped in ink on a white label. You should record this data above and keep it in a safe place for future use.

2

U.L. Model No.: CF160

Page 2
Image 2
Emerson CF160 owner manual Additional Safety Instructions for Installation

CF160 specifications

The Emerson CF160 is a sophisticated and versatile centrifugal fan designed specifically for various industrial applications. Renowned for its efficiency and reliability, the CF160 integrates advanced technologies that make it an ideal choice for air handling and ventilation systems.

One of the key features of the Emerson CF160 is its compact design, which allows for easy installation in spaces with limited room. Despite its small footprint, the CF160 can deliver an impressive air volume, making it suitable for use in commercial buildings, manufacturing facilities, and HVAC systems.

The fan is equipped with an energy-efficient motor that meets stringent environmental standards. This not only reduces operational costs but also supports sustainability efforts by minimizing energy consumption. The motor operates quietly, ensuring that the CF160 can be utilized in noise-sensitive environments without causing disruptions.

The CF160 boasts a robust construction, using high-quality materials that enhance its durability and longevity. The fan's housing is designed to withstand harsh conditions, making it suitable for both indoor and outdoor applications. Additionally, the components are engineered to resist corrosion, ensuring the fan's reliability over time.

Another notable characteristic of the Emerson CF160 is its adjustable airflow capability. Operators can easily modify the fan's settings to achieve the desired air movement, providing flexibility in various applications. This feature is particularly beneficial in environments where air flow requirements can change frequently.

The CF160 utilizes cutting-edge aerodynamic technology, allowing for optimized airflow and performance. The fan blades are designed to maximize efficiency, reducing turbulence and ensuring smooth operation. This design contributes not only to improved performance but also to reduced maintenance needs, further enhancing the fan's appeal.

Furthermore, the Emerson CF160 is equipped with advanced control systems that allow for seamless integration into smart building technologies. This enables real-time monitoring and management of airflow, ensuring optimal performance and energy usage.

In summary, the Emerson CF160 is a top-tier centrifugal fan characterized by its compact design, energy-efficient motor, durable construction, adjustable airflow, and advanced control technologies. It stands out as a reliable and efficient solution for various industrial and commercial ventilation needs, providing superior performance while supporting sustainability efforts.