BP7358 RUSTICO CF160 9/19/07 11:23 AM Page 10

STANDARD ON-OFF WALL

 

SWITCH OR OPTIONAL SW115

BLACK

WALL CONTROL

TO

BLACK

(HOT)

120-

 

VOLT

 

SUPPLY

 

 

WHITE

 

GROUND

Manual background BLACK

WHITE

WHITE

BLACK

TWO-CONDUCTOR

CABLE (WITH

GROUND)

GREEN WIRE (GROUND) Manual backgroundManual background

FROM HANGER BALL AND

HANGER BRACKET

Figure 13

BLUE WHITE ORANGE

Manual background BLACK

Manual background BLUE WHITE

Manual backgroundManual background ORANGE

Manual background HANGER BALL

Manual backgroundManual background 3. Push the wires and connectors up into the outlet box while inserting the receiv- er fully into the hanger bracket. Position the antenna wire on top of the receiver.

Manual backgroundManual background 4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 12).

Manual backgroundManual background 5. Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 13).

Manual backgroundManual background 6. Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). (Figure 14). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling.

CEILING

COVER

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

NOTE: If you wish to operate your ceil- ing fan with the downlight fixture attached, perform steps 7 and 8. Otherwise, skip to step 9.

Manual backgroundManual background 7. For Operating Your Fan With the Downlight Fixture. Remove the thread- ed plug from the light fitter adapter. Feed the black and white wires of the light fitter assembly through the hole in the adapter and screw the threaded nipple of the light fitter into the adapter hole (Figure 15). Install nut and lock- washer onto threaded nipple inside of adapter and securely tighten.

LOCKWASHERManual background

(2)

KNURLED

KNOB (2)

Figure 14

NUT

LOCKWASHER

 

LIGHT

 

FITTER

THREADED

ADAPTER

PLUG

 

THREADED

LIGHT FITTER

 

STUD (2)

 

Figure 15

THREADED

NIPPLE

10

U.L. Model No.: CF160

Page 10