Emerson CF2455ORB00, CF2455BS00, CF2455PW00 Electrical Requirements, Preliminary Procedures

Models: CF2455PW00 CF2455ORB00 CF2455BS00

1 16
Download 16 pages 35.32 Kb
Page 4
Image 4
Electrical Requirements

IMPORTANT: Your ceiling fan is supplied with an SW116 Fan/Light Wall Control (transmitter) and a remote control SW105 Receiver which mounts under the ceiling cover. This system allows you to regulate your ceiling fan speed, airflow direction, and light intensity. An optional Emerson Electric SR110 Remote Control may also be used.

IMPORTANT: Your ceiling fan will not function properly and may be damaged, if used with any wall dimmer switch or control other than the Emerson controls listed above.

Electrical Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit.

The outlet box must be securely anchored and capable of withstanding a load of at least 50 pounds.

!WARNING

To reduce the risk of fire, electric shock, or personal injury, mount fan to outlet box marked “Acceptable for Fan Support”, and use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing ceiling light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

!WARNING

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with national and local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

!WARNING

To avoid possible fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

Preliminary Procedures

IMPORTANT: Before assembling your ceiling fan, refer to sections “Setting Operating Frequency of Wall Control and Receiver” and “Battery Installation of Wall Control”, page 11. These sections instruct you how to:

a.Set the operating frequency of the fan/light wall control and the remote control receiver.

b.Install the fan/light wall control in the wall box.

You will then be ready to proceed with the assembly and installation of your ceiling fan.

Ceiling Fan Assembly

Procedures

1.Position the fan motor and housing assembly in the lower styrofoam packing so that the top for the motor is facing you.

2.Obtain the hanger ball/downrod assembly and remove the hanger ball by loosening the setscrew in the hanger ball until the ball falls freely down the downrod (Figure 1). Remove the pin from the downrod, then remove the hanger ball. Retain the pin and hanger ball for reinstallation in Step 11.

PIN

HANGER BALL

DOWNROD

SETSCREW

 

Figure 1

3.Using a wire connector (supplied), connect the yellow uplight lead (supplied) to the yellow wire from the motor (Figure 2).

4.Separate, untwist and unkink the three black, white and blue motor wires and the yellow uplight lead. Route these wires through the downrod.

5.Fold the wires from the downrod into the slot in the motor coupling. Then slide the downrod down the wires and seat the downrod in the motor coupling (Figure 2).

4