MaintenanceAccessories
IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan
Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.
1. Ceiling Fan Controls (see store or catalog).
2. Downrod Extension Kits (see store or catalog).
!WARNING
The use of any other control not specifically approved for this fan could result in fire, shock and personal injury.
!WARNING
Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock.
NOTE: Periodically check the tightness of the knurled knobs securing the light kit glass in the light kit adapter. Tighten if necessary.
!WARNING
This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage.
!WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.
Trouble Shooting
TROUBLE |
| PROBABLE CAUSE |
| SUGGESTED REMEDY |
|
|
|
|
|
1. Fan will not start. | 1. | Fuse or circuit breaker blown. | 1. | Check main and branch circuit fuses or circuit |
|
|
|
| breakers. |
|
|
| ! | WARNING: Make sure main power is turned off. |
| 2. | Loose power line connections to the fan. | 2. | Check line wire connections to fan |
| 3. | Fan/Light Wall Control is OFF. | 3. | Turn ON Fan/Light Wall Control. |
| 4. | Code switches in remote control/receiver are not | 4. | Check that both code switches are set in the same |
|
| set in the same position. |
| positions. |
|
|
|
|
|
2. Fan sounds noisy. | 1. | Blades not attached to fan. | 1. | Attach blades to fan before operating. |
| 2 | Screws holding blades to flanges are loose. | 2. | Tighten screws securely. |
|
|
|
|
|
3. Fan wobbles | 1. | Setscrew in motor coupling is loose. | 1. | Raise motor cover and tighten setscrew securely. |
excessively. | 2. | Setscrew in hanger ball/downrod assembly is | 2. | Tighten the setscrew in the hanger ball/downrod |
|
| loose. |
| assembly. |
| 3. | Hanger bracket and/or ceiling outlet box is not | 3. | Tighten the hanger bracket screws to the outlet box, |
|
| securely fastened. |
| and/or secure outlet box. |
| 4. | Fan blades out of balance. | 4. | Interchanging an adjacent |
|
|
|
| redistribute the weight and result in smoother operation. |
|
|
|
| Or use supplied balancing kit to balance blades. |
|
|
|
|
|
13