Trouble Shooting
! WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan.
TROUBLE |
| PROBABLE CAUSE |
| SUGGESTED REMEDY |
|
|
|
|
|
1. Fan will not start. | 1. | Fuse or circuit breaker blown. | 1. | Check main and branch circuit fuses or circuit |
|
|
|
| breakers. |
| 2. | Loose power line connections to the fan, | 2. | Check line wire connections to fan and switch |
|
| or loose switch wire connections in the |
| wire connections in the switch housing. |
|
| switch housing. | ! | WARNING: Make sure main power is |
|
|
|
| turned OFF. |
| 3. | Dead battery in remote control transmitter. | 3. | Replace battery (red indicator light on transmitter |
|
|
|
| should light when any button is pressed). |
| 4. | Remote control transmitter not programmed | 4. | See Remote Programming Procedures, page 9. |
|
| to match control receiver. |
|
|
|
|
|
|
|
2. Fan sounds noisy. | 1. | Blades not attached to fan. | 1. | Attach blades to fan before operating. |
| 2. | Loose screws in motor housing. | 2. | Check to make sure all screws in motor housing |
|
|
|
| are snug (not |
| 3. | Wire connectors inside switch housing | 3. | Check to make sure wire connectors in switch |
|
| rattling. |
| housing are not rattling against each other or |
|
|
|
| against the interior wall of the switch housing. |
|
|
| ! | WARNING: Make sure main power is |
|
|
|
| turned OFF. |
| 4. | Screws holding blades to flywheel | 4. | Tighten screws securely. |
|
| are loose. |
|
|
|
|
|
|
|
3. Fan wobbles | 1. | Setscrew in motor coupling is loose. | 1. | Tighten both setscrews securely in the motor |
excessively. |
|
|
| coupling. |
| 2. | Setscrew in hanger ball/downrod | 2. | Tighten the setscrew in the hanger ball/ |
|
| assembly is loose. |
| downrod assembly. |
| 3. | Screws securing fan blade flanges to | 3. | Check to be sure screws which attach the fan |
|
| flywheel are loose. |
| blade flanges to the motor are tight. |
| 4. | Hanger bracket and/or ceiling outlet | 4. | Tighten the hanger bracket screws to the outlet |
|
| box is not securely fastened. |
| box, and/or secure outlet box. |
| 5. | Fan blades out of balance. | 5. | Interchanging an adjacent |
|
|
|
| pair can redistribute the weight and result in |
|
|
|
| smoother operation. |
|
|
|
|
|
13 | Model No.: CF990 |