BP7308 LORRAINE KF240 2/15/06 3:21 PM Page 12

SW101 FAN/LIGHT WALL

CONTROL (SUPPLIED)

BLACK

TO (HOT)

120-

VOLT

SUPPLY

WHITE

GROUND

EMERSON

BLACK

BLACK

WHITE

WHITE

RED

TWO-CONDUCTOR

CABLE (WITH

GROUND)

GREEN WIRE (GROUND)

FROM HANGER BALL AND

HANGER BRACKET

Figure 15

BLUE WHITE

BLACK

BLUE

WHITE

HANGER BALL

3. Push the wires and connectors up into the outlet box while inserting the receiver fully into the hanger bracket. Position the antenna wire on top of the receiver.

4. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 14).

5. Lift the ceiling cover up to the threaded studs and turn until the studs protrude through the holes in the ceiling cover (Figure 16).

6. Secure the ceiling cover in place by sliding lockwashers (supplied) over the threaded studs and installing the two knurled knobs (supplied). (Figure 16). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling.

!WARNING

To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling.

7.Screw in three 40-watt (maximum) candelabra bulbs in the light fitter sockets (Figure 17). Carefully place the lower glass over the light fitter threaded nipple. Be sure the glass is firmly seated on the fitter, then secure in place using a rubber washer, metal washer, and 1/8-27 nut (washers and nut are supplied).

8.Place the decorative cap over the threaded nipple and then screw on the finial nut (Figure 17).

CEILING COVER

9. Your ceiling fan is now installed and

 

wired to be controlled by your fan/light

 

wall control.

LOCKWASHER (2) 1-1/4" THREADED

STUD (2)

KNURLED

 

KNOB (2)

Figure 16

12

Page 12
Image 12
Emerson KF240PRZ00 owner manual Your ceiling fan is now installed