Emerson KF240PRZ00 owner manual Trouble Shooting, Probable Cause, Suggested Remedy

Models: KF240PRZ00

1 20
Download 20 pages 44.32 Kb
Page 17
Image 17
Trouble Shooting

BP7308 LORRAINE KF240 2/15/06 3:21 PM Page 17

!WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting

TROUBLE

PROBABLE CAUSE

 

SUGGESTED REMEDY

 

 

 

 

1. Fan will not

1. Fuse or circuit breaker

1.

Check main and branch

start.

blown.

 

circuit fuses or circuit breakers.

 

 

!

WARNING: Make sure

 

 

 

main power is turned off.

 

2. Loose power line

2.

Check line power connections

 

connections to the fan.

 

to fan.

 

3. Fan/Light Wall Control is OFF.

3.

Turn ON Fan/Light Wall Control.

 

4. Code switches in remote

4.

Check that both code switches

 

control receiver and Fan/Light

 

are set in the same positions.

 

Wall Control are not set in the

 

 

 

same position.

 

 

 

 

 

 

2. Fan sounds

1. Blades not attached to fan.

1.

Attach blades to fan before

noisy.

 

 

operating.

 

2. Screws securing fan blade

2.

Check to make sure the screws

 

flanges to motor are loose.

 

which attach the blade flanges

 

 

 

to the motor are tight.

 

3. Screws holding blades to

3.

Tighten screws securely.

 

flanges are loose.

 

 

 

 

 

 

3. Fan wobbles

1. Setscrews in motor coupling are

1.

Raise decorative downrod cover

excessively.

not tightened securely.

 

and coupling cover and tighten

 

 

 

setscrews securely.

 

2. Setscrew in the hanger ball/

2.

Tighten the setscrew in the

 

downrod assembly is loose.

 

hanger ball/downrod assembly.

 

3. Screws securing fan blade

3.

Check to be sure screws which

 

flanges to motor are loose.

 

attach the fan blade flanges

 

 

 

to the motor are tight.

 

4. Fan blade flanges not seated

4.

Check to be sure that the

 

properly.

 

screws securing the fan

 

 

 

blade flanges seat firmly.

 

5. Hanger bracket and/or ceiling

5.

Tighten the hanger bracket

 

outlet box is not securely

 

screws to the outlet box, and/or

 

fastened.

 

secure outlet box.

 

6. Fan blades out of balance.

6.

Interchanging an adjacent (side

 

 

 

by-side) blade pair can

 

 

 

redistribute the weight and result

 

 

 

in smoother operation.

 

 

 

Or use supplied balancing kit to

 

 

 

balance blades.

 

 

 

 

17

Page 17
Image 17
Emerson KF240PRZ00 owner manual Trouble Shooting, Probable Cause, Suggested Remedy