Emerson SZO56, SZO44, SZV44, SZV32 Configuration Suction, Max Flow/HP as a function of discharge

Models: SZV44 SZO44 SZO56 SZV32

1 44
Download 44 pages 48.85 Kb
Page 35
Image 35

Dual-Compressor Module

Technical Support and Service

Compressor Module

Horsepower Selection Chart

Module Model Number: SZV32C1A-EDE-150

Configuration

Suction

MCFD

Max Flow/HP as a function of discharge

 

Press

 

pressure at maximum flow rate (Note 1)

 

(PSIG)

 

 

 

 

 

 

 

 

 

150

175

200

225

250

275

 

 

 

 

 

 

 

 

 

 

 

 

One Module Package

0

MCFD

50

49

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HP

18

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

MCFD

87

86

85

84

83

81

 

 

 

 

 

 

 

 

 

 

 

HP

19

21

23

25

27

30

 

 

 

 

 

 

 

 

 

 

25

MCFD

144

142

141

139

139

137

 

 

 

 

 

 

 

 

 

 

 

HP

21

23

25

27

29

31

 

 

 

 

 

 

 

 

 

 

50

 

241

238

236

233

232

 

 

 

 

 

 

 

 

 

 

 

 

 

23

25

27

30

32

 

 

 

 

 

 

 

 

 

 

 

65

 

304

297

295

291

291

 

 

 

 

 

 

 

 

 

 

 

 

 

24

26

28

31

33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Two Module Package

0

 

100

98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

39

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

174

172

170

168

166

162

 

 

 

 

 

 

 

 

 

 

 

 

38

42

46

50

54

60

 

 

 

 

 

 

 

 

 

 

25

 

288

284

282

278

278

274

 

 

 

 

 

 

 

 

 

 

 

 

42

46

50

54

58

62

 

 

 

 

 

 

 

 

 

 

50

 

 

482

476

472

466

464

 

 

 

 

 

 

 

 

 

 

 

 

46

50

54

60

64

 

 

 

 

 

 

 

 

 

 

 

65

 

 

608

594

590

582

582

 

 

 

 

 

 

 

 

 

 

 

 

48

52

56

62

66

 

 

 

 

 

 

 

 

 

 

NOTES:

1.Max flow using varibable speed drive, compressors operating at 80 Hz. max speed.

2.Standard test conditions: 60° F suction gas, 60° F ambient, 0.6 SG gas, 14.7 psia = 0 psig

3.Performance data to be used as an estimation guide only and is subject to change without notice

29

2006SSD-75 R4 (10/10)

Page 35
Image 35
Emerson SZO56, SZO44, SZV44, SZV32 manual Configuration Suction, Max Flow/HP as a function of discharge