ESSENTIAL INSTRUCTIONS
READ THIS PAGE BEFORE PROCEEDING!
Rosemount Analytical designs, manufactures, and tests its products to meet many national and international standards. Because these instruments are sophisticated technical products, you must properly install, use, and maintain them to ensure they continue to operate within their normal specifications. The following instructions must be adhered to and integrated into your safety pro- gram when installing, using, and maintaining Rosemount Analytical products. Failure to follow the proper instructions may cause any one of the following sit- uations to occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty invalidation.
•Read all instructions prior to installing, operating, and servicing the product. If this Instruction Manual is not the correct manual, telephone
•If you do not understand any of the instructions, contact your Rosemount representative for clarification.
•Follow all warnings, cautions, and instructions marked on and supplied with the product.
•Inform and educate your personnel in the proper installation, operation, and maintenance of the product.
•Install your equipment as specified in the Installation Instructions of the appropriate Instruction Manual and per applicable local and national codes. Connect all products to the proper electrical and pressure sources.
•To ensure proper performance, use qualified personnel to install, operate, update, program, and maintain the product.
•When replacement parts are required, ensure that qualified people use replacement parts specified by Rosemount. Unauthorized parts and proce- dures can affect the product’s performance and place the safe operation of your process at risk. Look alike substitutions may result in fire, electrical hazards, or improper operation.
DANGER
HAZARDOUS AREA
INSTALLATION
This sensor is not Intrinsically Safe. or Explosion Proof. Installations near flammable liquids or in hazardous area locations must be carefully eval- uated by qualified on site safety personnel.
To secure and maintain an intrinsically safe installation, an appropriate transmitter/ safety barrier/sensor combination must be used. The installation system must be in accordance with the governing approval agency (FM, CSA or BASEEFA/CENELEC) hazardous area classifi- cation requirements. Consult your analyzer/ transmitter instruction manual for details.
Proper installation, operation and servicing of this sensor in a Hazardous Area Installation is entirely the responsibility of the user.
CAUTION
SENSOR/PROCESS
APPLICATION COMPATIBILITY
The wetted sensor materials may not be compatible with process composition and operating conditions. Application compatibility is entirely the responsibility of the user.
About This Document
This manual contains instructions for installation and operation of the Models 396P and 396PVP TUpH Combination pH/ORP Sensors. The following list provides notes concerning all revisions of this document.
Rev. Level | Date | Notes |
0
A12/01 Added wiring diagram to page 14.
B4/02 Revised drawings on pages 6, 7, and 14.
C7/02 Added 1055 wiring diagrams.
D8/03 Added Silcore information.
E5/04 Added 5081 and Xmt wiring info. Deleted obsolete model information.
G11/05 Changed Figure
H3/06 Changed PN on Fig.