MODEL 396P and 396PVP

SECTION 4.0

 

WIRING - MODEL 396PVP

SECTION 4.0

WIRING — MODELS 396P-02 AND 396PVP

Figures 4-1 thru 4-22 provide the guidelines for wiring the sensor to various Analyzer/Transmitter instruments.

To determine which wiring guideline to use, locate the model number of the sensor to be installed.

1.If the cable needs to be extended, use a high qual- ity eleven conductor double shielded instrument cable available from Rosemount Analytical. Refer to Table 4-1 to refer to the appropriate junction box to use and the corresponding wiring details.

NOTE

If the cable is too long, loop up the excess cable. If the cable has to be shortened, cut and terminate each conductor neatly and make sure that the overall (outermost) drain wire is not shorted out with either of the two inner drain wires (shields).

2.Signal cable should be run in a dedicated conduit (preferably an earth grounded metallic conduit) and should be kept away from AC power lines. For your convenience, a wire nut kit is furnished (in a plastic bag wrapped around the cable).

NOTE

For maximum EMI/RFI protection when wiring from the sensor to the junction box, the outer braid of the sensor should be connected to the outer braided shield of the extension cable. The outer braid of the extension cable to the instrument must be terminated at earth ground or by using an appropriate metal cable gland fitting that provides a secure connection to the instrument cable.

TABLE 4-1. Wiring Matrix Guide

 

Preamplifier Location

 

 

Analyzer/Transmitter

 

 

 

Sensor

Integral to

Integral to

Remote

Interconnect

1054A,

54, 81, 1055 1181

1050

1003

SCL or

Refer to

Model

Sensor

Analyzer

Junction

(unprepped

1054B, 2054

3081,

1060

1023

SoluCube

Figure

Options

 

 

Box (PN)

PN)

2081

4081, 5081

 

 

 

#

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-55

 



 

 

 



 

 

 

4-3, 4-6,

396PVP-55

 

 

 

 

 

 

 

 

 

4-9

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-50

 



 

 

 



 

 

 

4-4

396PVP-50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-50

 

 

23309-03

9200254

 







 

4-22

396PVP-50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-50

 

 

23309-03

9200273 or

 







 

4-8

396PVP-50

 

 

 

23646-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-54

 

 

23309-04

9200254



 

 

 

 

4-23

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-54

 

 

23309-04

9200273 or



 

 

 

 

4-20

396PVP-54

 

 

 

23646-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-54

 



 

 



 

 

 

 

4-5, 4-18

396PVP-54

 

 

 

 

 

 

 

 

 

4-19

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-55

 

 

23555-00

9200273 or

 



 

 

 

4-7, 4-10

396PVP-55

 

 

 

23646-01

 

 

 

 

 

4-12

 

 

 

 

 

 

 

 

 

 

 

396P-02-()-54

 



 

661-898695

 

 

 

 



4-14

396PVP-54

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-02-54

 

 

23309-04

9200273 or



 

 

 

 

4-11

396PVP-54

 

 

 

23646-01

 

 

 

 

 

4-21

 

 

 

 

 

 

 

 

 

 

 

396P-02-55

 



 

 

 



 

 

 

4-15

396PVP-55

 

 

 

 

 

 

 

 

 

4-16

 

 

 

 

 

 

 

 

 

 

 

396P-02-55

 

 



9200273 or

 



 

 

 

4-17

396PVP-55

 

 

 

23646-01

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

Page 20
Image 20
Emerson Process Management instruction manual Section Wiring Models 396P-02 and 396PVP, Refer to

396P, 396PVP specifications

Emerson Process Management has established itself as a leader in the automation industry, providing innovative solutions that enhance operational efficiencies and improve process control. Among its notable offerings are the 396PVP and 396P pressure transmitters, designed to meet the needs of various industrial applications.

The 396PVP model is equipped with advanced features that facilitate high-performance measurements in both challenging and standard environments. This pressure transmitter utilizes a piezoresistive sensor, allowing for accurate and reliable pressure readings. It supports a wide range of measurement capabilities, making it suitable for liquids, gases, and vapors across diverse industries. With an impressive pressure range, the 396PVP caters to various applications, from HVAC systems to more demanding scenarios in oil and gas extraction.

In terms of technology, the 396PVP leverages digital communication protocols, including HART and FOUNDATION Fieldbus, enabling seamless integration into existing control systems. This capability not only enhances data transmission but also facilitates remote monitoring and diagnostics, significantly reducing downtime and maintenance requirements. The transmitter is also designed with an intuitive interface, allowing for straightforward configuration and calibration via handheld devices or software.

On the other hand, the 396P model offers exceptional performance for demanding pressure measurement requirements. It features robust construction materials that ensure durability and resistance to harsh environments, making it an ideal choice for applications in chemical processing and power generation. The 396P is designed with a fast response time, ensuring real-time data accuracy, which is critical for maintaining process integrity and safety.

Both models showcase Emerson's commitment to safety and reliability. They are built to meet stringent industry standards, which guarantees quality performance in hazardous locations. Furthermore, the embedded diagnostic features provide real-time health monitoring, alerting operators of any potential issues before they escalate, thereby safeguarding operations.

In summary, the 396PVP and 396P pressure transmitters from Emerson Process Management exemplify cutting-edge technology and high-quality engineering. With their advanced sensing capabilities, robust design, and integration-friendly features, these transmitters are essential tools for optimizing process control and enhancing overall productivity in various industrial settings. Whether it's for precise measurements in a chemical plant or reliable pressure readings in an oil field, the 396 series offers the performance and durability required to thrive in today's demanding operational landscapes.