SECTION 3.0

MODEL 396P and 396PVP

SECTION 3.0

 

WIRING - MODEL 396P

SECTION 3.0

WIRING — MODEL 396P-01

Figures in this section provide the guidelines for wiring the 396P-01 sensor to various Analyzer/Transmitter instruments.

To determine which wiring guideline to use, locate the model number of the sensor to be installed.

1.If the cable needs to be extended, use a high qual- ity eleven conductor double shielded instrument cable available from Rosemount Analytical. Refer to Table 3-1 for the appropriate junction box to use and the corresponding wiring details.

NOTE

If the cable is too long, loop up the excess cable. If the cable has to be shortened, cut and terminate each conductor neatly and make sure that the overall (outermost) drain wire is not shorted out with either of the two inner drain wires (shields).

2.Signal cable should be run in a dedicated conduit (preferably an earth grounded metallic conduit) and should be kept away from AC power lines. For your convenience, a wire nut kit is furnished (in a plastic bag wrapped around the cable).

NOTE

For maximum EMI/RFI protection when wiring from the sensor to the junction box, the outer braid of the sensor should be con- nected to the outer braided shield of the extension cable. The outer braid of the extension cable to the instrument must be terminated at earth ground or by using an appropriate metal cable gland fitting that provides a secure connection to the instru- ment cable.

TABLE 3-1. Wiring Matrix Guide

 

 

Preamplifier Location

 

 

 

Analyzer/Transmitter

 

 

 

 

 

Sensor

 

Integral to

Integral to

Remote

Interconnect

1054A,

54e, 81,

1055 1181

1050

1003

SCL or

 

Refer to

 

Model

 

Sensor

Analyzer

Junction

(unprepped

1054B, 2054

3081,

 

1060

1023

SoluCube

 

Figure

 

Options

 

 

 

Box (PN)

PN)

2081

4081, 5081

 

 

 

 

#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-01-()-50



 

 

 

 

 





 

 

3-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-01-()-50



 

Ext. box

9200254

 

 





 

 

3-2

 

 

 

 

 

(22719-02)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-01-()-54



 

 

 



 

 

 

 

 

3-3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-01-()-54



 

Ext. box

9200254



 

 

 

 

 

3-3

 

 

 

 

 

(22719-02)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-01-()-55



 

 

 

 



 

 

 

 

3-5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-01-()-55



 

Ext. box

9200273

 



 

 

 

 

3-4

 

 

 

 

 

(23550-00)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

396P-01-()-55



 

 

9200273

 

 



 

 

 

3-6

 

 

 

 

 

 

or 23646-01

 

 

 

 

 

 

 

 

 

10