Multi-zone Condenser Sequence of Operation
www.enviromaster.com

Multi-zone Condenser Sequence of Operation

EMI America Series multi-zone heat

by providing comfort cooling or heating to

pump condensers are designed to operate

the indoor space. The reversing valve is

with EMI America Series indoor air han-

energized in cooling. Should the valve fail

dlers. Both the condenser (outdoor unit)

to actuate, the system will default to the

and evaporator (indoor unit) have a high

heating mode of operation.

 

Volt service connection. Each is to be inde-

 

 

pendently connected to the electrical ser-

Cooling operation, Multi-zone Heat

vice panel. (See the unit name plate for the

Pump:

 

correct breaker type and size). The outdoor

Cooling mode operation requires that the

and indoor units are also connected to each

control (either unit mount or remote wall

other through a low Volt interconnect wiring.

mount thermostat) make a connection be-

A 24v transformer located in the indoor unit

tween low-Volt terminals “R” and “Y” along

provides the low Volt power source.

with “R” and “O”. When the indoor control

The S & T series (S2HB, T2HB, T3HB &

is placed in cooling mode, with the set point

temperature below the room temperature,

T4HB) heat pumps will provide comfort

the reversing valve will energize (R & O)

cooling or heat pump operation operate

along with the compressor and outdoor fan

at an outdoor temperature range between

(R & Y). When the indoor control is satis-

35°F and 115°F for cooling, 0°F and 75°F

fied and the room temperature falls below

for (heat pump) heating.

the set temperature, the compressor and

The S & T series (S2HB, T2HB, T3HB

fan will de-energize. The EMI indoor unit

& T4HB) heat pump condensers are de-

is equipped with an anti-short cycle timer

signed to operate as a single stage cool-

(ASCT) will prevent the compressor from

ing, two stage heating unit. For full opera-

re-starting for three minutes.

 

tion the unit should be matched with an

 

 

appropriate EMI indoor unit with electric

Heating operation, Multi-zone Heat

heat and unit mounted controls or a wall

Pump:

 

mounted thermostat.

Heating mode operation requires that the

For two stage heating operation the indoor

control (either unit mount or remote wall

mount thermostat) make a

connection

unit must be equipped with an electric strip

between low-Volt terminals

“R” and “Y”

heater.

only. When the indoor control is placed

 

See the instruction manual for the indoor

in heating mode, with the set point tem-

unit on the selection of the proper thermo-

perature above room temperature, the

stat for the system.

compressor and outdoor fan (R & Y) will

 

energize. When the indoor control is satis-

Condenser Operation:

fied and the room temperature rises above

The transformer located in the indoor unit

the set temperature, the compressor and

provides 24V, low-Volt control power to the

fan will de-energize. The EMI indoor unit

condenser (outdoor unit). This can be mea-

is equipped with an anti-short cycle timer

sured across low-Volt terminals “R” and “C”.

(ASCT) will prevent the compressor from

 

re-starting for three minutes.

 

Heat pump condensers utilize a reversing

Note: For full operation the indoor unit

valve to provide reverse cycle operation.

Therefore the outdoor unit will act as ei-

must have an electric heater.

ther a condenser or an evaporator there-

Multi-zone Heat Pump Condensing Units 20

Page 20
Image 20