EMI S2HB dimensions and specifications, specifications may change without notice, Model, Total

Models: S2HB T2HB T3HB T4HB

1 32
Download 32 pages 9.46 Kb
Page 23
Image 23
S2HB dimensions and specifications

S2HB dimensions and specifications

Note: All EMI products are subject to ongoing development programs so design and

specifications may change without notice.

15”

38”

44”

Easy access interconnects

 

on back of unit

 

1/2” Diameter Lag Holes

 

 

 

Front of unit

 

 

 

 

 

 

Electrical

 

 

 

 

 

3.00”

 

 

 

 

 

 

connections

 

 

 

 

 

 

 

 

 

 

 

 

 

12.44”

 

 

 

 

 

 

 

 

 

7”

 

23.94”

7”

 

 

 

 

 

 

 

 

 

 

S2HB ELECTRICAL SPECIFICATIONS

MODEL

 

FAN

COMPRESSOR 1

COMPRESSOR 2

TOTAL

MIN. CIR.

HACR

(1)

VOLTS/HZ/PHASE

RLA

HP

RLA

LRA

RLA

LRA

AMPS

AMPS

BRKR

 

(2)

 

 

 

 

 

 

 

 

 

 

9900

208-230/60/1

1.8

0.33

3.4

23

3.4

23

8.6

9.5

15

2200

208-230/60/1

1.8

0.33

4.3

27

4.3

27

10.4

11.5

15

9200

208-230/60/1

1.8

0.33

3.4

23

4.3

27

9.5

10.6

15

(1)Circuit Designators: 9 = 9,000 Btuh • 2 = 12,000 Btuh (ex. - Model 9200 consists of one 9,000 Btuh compressor and one 12,000 Btuh compressor)

(2)Always refer to the rating plate for Minimum Circuit Ampacity on all multiple compressor units.

S2HB PIPING SPECIFICATIONS

Sound Data

Shipping

Model#

Line Sizes

Weight

 

Liquid

Suction

dbA

Lbs.

 

9900

1/4”

1/2”

64

159

2200

1/4”

1/2”

65

197

9200

1/4”

1/2”

65

187