Energy Tech Laboratories Modular Direct Fired Heaters manual Remote Panel Troubleshooting Chart

Models: Modular Direct Fired Heaters

1 28
Download 28 pages 34.52 Kb
Page 22
Image 22

Remote Panel Troubleshooting Chart

Light Indication

Condition

Possible Cause

No Lights

Power not available to Remote Panel

Bad voltage to unit

 

 

Main disconnect in “OFF” Position

 

 

Circuit breaker tripped

 

 

Bad main transformer

POWER Light Only

Proper unit Off Operation

No problem

 

No power to motor starter

Manual/Off/Auto Switch in “Off” Position

 

 

(3 Position Remote Panels Only)

 

 

Improper damper function

 

 

Low Temperature Thermostat Timed

 

 

Out (Option)

POWER Light and

Proper Ventilation Operation

No Problem

BLOWER ON Light

No Power to Flame Safety Controller

Manual/Off/Auto Switch in “Off” Position

 

 

(2 Position Remote Panels Only)

 

 

Heat/Vent Switch in “Vent” Position

 

 

Gas Pressure Switch Tripped (option)

 

 

High Temperature Limit Thermostat

 

 

Tripped

 

 

Manual/Off/Auto Switch in “Auto”

 

 

Position and Intake Air Thermostat not

 

 

Satisfied

 

Improper Airflow

Insufficient Airflow

 

 

Excessive Airflow

 

 

Bad airflow switch

 

 

Problem with air probes

 

 

Problem with airflow tubing

 

 

Broken Belt

POWER Light and

Proper Heating Operation

No Problem

BLOWER ON Light and

 

 

BURNER ON Light

 

 

CLOGGED FILTER Light On

Filters Clogged

Filters Dirty or Need Replacement

(Optional)

 

 

FLAME FAILURE Light On

Flame Safety Alarm Activated

Combination Valve in “Off” Position

 

No Flame Detected during Pilot

(Unit Sizes 1-3)

 

Stuck Closed Gas Valve

 

Establishment Period

No or Low Gas Pressure

 

 

Bad Spark Electrode

 

 

Bad Ignition Transformer

 

 

Flames Sensor Malfunction

 

 

Clogged Pilot Orifices