Overview of DFE Module Shutdown Procedure
Enterasys Matrix DFE-Gold Series PoE Module Hardware Installation Guide 4-11

Figure 4-3 OFFLINE/RESET Switch

Recommended Shutdown Procedure Using OFFLINE/RESET Switch

BeforepullingaDFEmoduleoutofachassis,

pressortaponitsOFFLINE/RESETswitchforlessthan1second.

ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicating

thattheDFEmoduleisshuttingdown.AttheendoftheDFEmoduleshutdownroutine,

theCPULEDchangestoa67%/33%sequenceofamber/off,respectively,indicatingthe

moduleisinahaltstate.InthistimeitissafetorestartorremovetheDFEmodulefrom

thechassis.

WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESETswitch,youhave60

secondsfromthetimetheCPUstartsflashingamber/offuntilthetimethedeviceis

automaticallyrestarted.

1OFFLINE/RESET switch (in similar location on all DFE modules)

COMOFFLINE / RESETCPUMGMTGROUP 1 GROUP 2 GROUP 31X
À
4G4205-72
Gb ENET
À
CPUPOE1XGROUP1
OFFLINE/
RESET
COMMGMT
GROUP
SELECT
GROUP
1
2
3
4
5
6
1
2
3
4
4G4285-49
Gb ENET

Caution: Do not pull any DFE module out of an operating chassis before it has completed

its shutdown routine.

Precaución: No retire los módulos DFE del chasis en funcionamiento hasta que no se

haya terminado con la rutina de apagado.

Note: The only safe time to pull a DFE module out of the chassis is when the CPU LED is

blinking amber. Otherwise, system operation will be interrupted.