Installation

OUTSIDE VERTICAL INSTALLATIONS:

To accomplish a outside vertical pipe installation, follow steps 1 through 5 in the “INSIDE VERTICAL INSTALLATIONS

-FREESTANDING” section and then finish it by performing the following (refer to Figure 14).

1.Install a tee with clean out on the outside of the house.

2.Install vent pipe upward from the tee. Make sure that you install support brackets to keep the vent straight and secure.

3.Install ceiling thimble and secure the flashing as you go through the roof.

4.Ensure that the rain cap is approximately 900 mm (36”) above the roof.

Rain cap

Flashing

900mm

(36")

75mm (3")

Clearance

100mm

(4")

Support

bracket

Tee with

cleanout

Type "L"

vent

Fresh air

intake

Figure 14: Outside Vertical Installation.

15

Page 15
Image 15
Enviro 50-1578 technical manual Outside Vertical Installation