Enviro 50-1578 technical manual Exhaust

Models: 50-1578

1 31
Download 31 pages 25.38 Kb
Page 10
Image 10

 

 

 

 

Installation

EXHAUST AND FRESH AIR INTAKE LOCATIONS:

 

 

8

3/8

4 3/8

12 7/8

 

 

(214 mm)

(112 mm)

(326 mm)

 

 

 

 

 

 

INSTALL VENT AT CLEARANCES SPECIFIED

 

 

 

 

 

BY THE VENTING MANUFACTURER

8

1/2

 

 

10

1/2

 

 

(265 mm)

(216 mm)

 

 

 

 

 

 

Figure 6: Inlet and Outlet Location.

 

EXHAUST

 

 

Base of unit to center of flue

270 mm

(10 5⁄8”)

Side of unit to center of flue

308 mm

(12 1⁄8”)

Center of unit to center of flue

19 mm

(3⁄4”)

FRESH AIR INTAKE.

 

 

Base of unit to center of intake

222 mm

(8 3⁄4”)

Side of unit to center of intake

197 mm

(7 3⁄4”)

Center of unit to center of flue

130 mm

(5 1⁄8”)

OUTSIDE FRESH-AIR CONNECTION:

This Heater must have adequate air for proper combustion in the room that it is installed.

A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures.

The inlet to the intake must be below and a minimum of 305mm (12”) away from the unit exhaust outlet.

Outside fresh air is mandatory when installing this unit in airtight homes.

When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 50mm minimum (2”) ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep the number of bends in the pipe to a minimum.

�������

����

���� ��

 

 

 

��������

��� ���

 

 

 

�����

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 7: Outside Air Connection.

10

Page 10
Image 10
Enviro 50-1578 technical manual Exhaust