Enviro 50-1578 technical manual Hearth Mount Side View

Models: 50-1578

1 31
Download 31 pages 25.38 Kb
Page 16
Image 16

Installation

HEARTH MOUNT INSTALLATION:

Clean-out

Fresh-air intake should com from chimney. If holes lready exist fresh-air intake can be taken through back of the fireplace or through the ash dump.

Damper Removed or Fastened Open

Mantel

Minimum 200mm (8") from top of stove

Min 150mm

(6")

Floor

Protection

Masonry Fireplace

Combustible Floor

Rain cap - ensure cap is at least 900mm (3 ft) above the roof at the lowest point

Figure 15: Hearth Mount - Side View.

Storm Collar

1.Lock fireplace damper in the open position.

2.Install a positive flue connector at the fireplace dampers.

3.Connect a clean-out tee or a 90° elbow to the exhaust pipe.

4.Install flexible stainless steel liner or listed pellet vent to the top of the chimney.

Seal Plate

Existing Masonary Flue

Vertical Vent Pipe (single wall stainless flex pipe or solid PL vent)

Flexible Vent Connector (use this 1.5m (5ft) section of pipe to vent past the fireplace damper or smoke shelf)

Fireplace Damper

Location

Clean Out Tee

Existing Fireplace

ENVIRO Windsor

Figure 16: Hearth Mount - Over View.

16

Page 16
Image 16
Enviro 50-1578 technical manual Hearth Mount Side View