Enviro C-11150 technical manual Installation, Exhaust, Fresh Air Intake

Models: C-11150

1 34
Download 34 pages 57.64 Kb
Page 10
Image 10
EXHAUST

Installation

OUTSIDE FRESH-AIR CONNECTION:

Outside fresh air is mandatory when installing this unit in airtight homes and mobile homes.

A Fresh-air intake is strongly recommended for all installations. Failure to install intake air may result in improper combustion as well as the unit smoking during power failures.

When connecting to an outside fresh air source, do not use plastic or combustible pipe. A 2” minimum (51

mm)ID (inside diameter) steel, aluminum or copper pipe should be used. It is recommended, when you are installing a fresh air system, to keep the number of bends in the pipe to a minimum.

�������

����

�� ��

��� ���

��������FRESH AIR INTAKE.Manual background

�����

EXHAUST AND INTAKE LOCATIONS:

Figure 7: Outside Air Connection.

101/16"

(255mm)

61/8"

(156mm)

21/16"

(53mm)

Figure 8: Mini Inlet and Outlet Location.

EXHAUST

 

 

Base of unit to center of flue

10 1/16(255 mm)

Center of unit to center of flue

0”

(0 mm)

 

[at center of unit]

FRESH AIR INTAKE.

 

 

Base of unit to center of intake

61⁄8”

(156 mm)

Center of unit to center of intake

21/16

(53 mm)

10

Page 10
Image 10
Enviro C-11150 technical manual Installation, Exhaust, Fresh Air Intake