Follow these steps to replace the lamp and air filter:

1.Turn off the projector and unplug the power cord.

2.Let the projector cool for at least an hour (if it has been on). The lamp is extremely hot immediately after use.

3.Loosen the lamp cover screw (you don’t need to remove it). Then slide the lamp cover to the side and lift it off of the projector.

4.Loosen the two screws holding the lamp in place (you can’t remove them).

warning

Let the lamp cool fully before replacing it.

In the unlikely event that the lamp has broken, small glass fragments may be present and should be removed carefully to avoid injury.

If the lamp is used after the replacement period has passed, the possibility that the lamp may break increases. When a lamp replacement message appears, replace the lamp with a new one as soon as possible, even if it is still working.

Loosen, but don’t remove these screws

Maintaining the Projector 67