LQ-670 Service Manual
Rev. A 5-11
5.3 Repairing the Power Supply Circuit BoardThis section explains problems related to the power supply circuit board(C214PSB). Since the table below
lists likely causes according to the order of frequently seen symptoms, find an appropriate symptom and
check the checkpoint.
Symptom Condition Cause Chec kpoint Solution
Normal voltage
is not output. Even the fuse F1
is replaced, it
shorts soon.
Line filter
circuit is
broken.
Check if C4 or L1 from C1
is connected to the AC line. Replace
appropriate parts.
Rectifier/smo
othing circuit
is defective.
•Check if DB1 is connected
to AC line or not.
•Check all elements on the
+ side of the primary side
such as C11 and T1.
If DB1 shorts, there is a
possibility that it happened
because of short circuit
occurred in the end of the
circuit.
Replace the power
supply board, DB1
or appropriate
parts.
All output voltage
is defective.
•If +42V is not
output normally,
other voltages
become
abnormal.
Diode bridge
DB1 is
defective.
Check if DC voltage(about
170V in case of 124PSB) is
output between + terminal
(pin 3) and − terminal(pin 4)
of CB1.
•There is a possibility that
output voltage of DB1 is not
output because of the
defective elements in the
end of the circuit.
Replace the power
supply board, DB1
or appropriate
parts.
Switching
FET Q1 is
defective.
Check the waveform (pin
11) of the coil in the T1 on
the primary side and also if
the switching operation of
Q1 is normal or not.
Figure 5-9. Waveform of
the Switching
Replace the power
supply board, Q1
or appropriate
parts.
Table 5-8. Repairing the C214PSB Board