LQ-670 Service Manual
Rev. A
3-14
3.2.10 PW Detector (Top) Removal
1. Remove [HOUSING, UPPER] (See Section 3.2.1)
2. Remove the Printhead (See Section 3.2.6)
3. Remove the Paper Exit Assy. (See Section 3.2.8)
4. Remove the Ribbon Mask Holder (See Section 3.2.9)
5. Remove one screw (CB/M2.5x6) fixing the PW Detector (Top) and remove it.
When you fixing the PW Detector (Top) to the Ribbon Mask Holder, be careful not to
damage a screw hole on the Ribbon Mask Holder.
z
Tightening Torque:0.1±0.02Nm (1.0±0.2Kgf-cm)
CR Guide Shaft
ROLLER, PF, DRIVE
CARRIAGE ASSY.
(viewed from right-hand side)
RIBBON MASK HOLDER
PW DETECTOR
Cable
(to PW DETECTOR)
Figure 3-11. Cable Rooting
CAUTION
CB (M2.5x6)
PW DETECTOR
RIBBON MASK HOLDER
Figure 3-12. PW DETECTOR Removal