Chapter 1 Product Description
Rev. A 1-2
9
1.4.4 Initialization
Power-On initialization
The initialization of this level is activated by power-on or cold reset command(remote RS command).
This initialization is;
to initialize the printer mechanism.
���to execute Operator initialization.
Operator Initialization
The initialization of this level is activated by /INIT signal(negative pulse). This initialization is;
to clear the all buffers of data.
to cancel the download character definition.
to make the printer stand-by state, if no errors occur.
to execute Software initialization.
Software Initialization
The initialization of this level is activated by the control code ESC @. This initialization is;
to clear the unprinted data.
to make the printer’s setting defaults.
1.4.5 Errors
This printer goes to the error state when the following condition is detected, and changes ERROR signal
to ”LOW” and “BUSY” signal to “HIGH” , and stops taking data. Also, the printer goes unprintable condition
automatically.
Fatal errors is detected.
Paper out error or paper jam error is detected.
Paper eject error is detected.
When the present paper path and the position of release lever do not match. (Release lever
operation error)
Fatal errors
Carriage control error, Power supply voltage error and CG access error.
Paper out error
When printer fails to load a sheet, it goes paper out error.
Paper eject error
When printer fails to eject a sheet, it goes paper eject error.
Paper jam error
When printer fails to feed a sheet, it goes paper jam error.