Maintenance

Replacing Consumables
Replacing the Air Filter

Dispose of used air filters properly in accordance with your local regulations.

Air filter frame:

ABS plastic

Air filter: Polypropylene

Turn off the power, wait for the cool-down period to finish (takes approximately 30 seconds), then disconnect the power cable.

Remove the air filter cover.

Put your finger under the latch. Lift up.

Replacing the Lamp

If the lamp stops working and needs to be replaced, there is the danger that the lamp may already be broken. If replacing the lamp of a projector which has been installed on the ceiling, you should always assume that the lamp is broken and handle it with extreme care during removal. Furthermore, you should stand to the side of the projector, not underneath it.

Turn off the power, wait for the cool-down period to finish (takes approximately 30 seconds), then disconnect the power cable.

*Wait until the lamp cools down (takes approximately 1 hour).

Install the new lamp.

Make sure that it faces the correct way.

Loosen the screws fixing the lamp cover.

Securely tighten the lamp fixing screws.

Resetting the Lamp Operating Time

The lamp operating time must always be reset after the lamp has been replaced with a new one.

The projector has a built-in lamp operating time counter. A replacement message is displayed when the counter reaches a certain amount.

Press

to turn on

Press

to display

the power.

the configuration menu.

42