A-8 Technical Specifications
PapU-U
Rev. C
A5 size APP-A.FM
2/1/00 Pass 0
LProof Sign-off:
E.Omori _______
<leadername> _______
<editorname> _______
Initialization Methods
The scanner can be initialized (returned to a fixed set of conditions) in the
following ways:
SCSI model
USB model
Hardware initialization * The scanner is turned on.
* The scanner receives a SCSI Reset signal from the SCSI
interface.
Software initialization * Software sends the ESC @ (initialize the scanner)
command.
* The scanner receives a SCSI Bus Device Message.
Hardware initialization * The scanner is turned on.
* The USB cable is unplugged from the USB port
on the scanner.
Software initialization * Software sends the ESC @ (initialize the scanner)
command.
* The scanner receives a Bus Reset from the USB
interface.