TM-C100 Technical Reference Guide

Appendix A

Product Specifications of the TM-C100

A.1 Product Specifications

Item

Specification

 

 

 

 

 

 

Interface (compatible)

USB

 

 

 

 

Power supply

Power supply with a dedicated AC adapter

 

 

Input voltage (rated)

Input voltage (rated) 90 (100 - 10%) to 264 (230 + 15%) VAC

 

 

 

 

Frequency (rated)

47 to 63 Hz

 

 

 

 

 

 

Power consumption

Operating

Average:

Approximately 11 W

 

 

Peak:

Approximately 13 W

 

Idling

Average:

Approximately 1 W

 

 

 

Applicable standards

Europe:

CE marking EMC Directive: 89/336/EEC

 

 

EN55022 Class B

 

 

EN55024

 

 

 

IEC61000-4-2

 

 

IEC61000-4-3

 

 

IEC61000-4-4

 

 

IEC61000-4-5

 

 

IEC61000-4-6

 

 

IEC61000-4-11

 

 

Safety standard: TÜV (EN 60950)

 

 

 

 

North

EMI: FCC/ICES-003 Class A

 

America:

Safety Standard: UL 60950/CSA C22.2 No. 60950

 

 

 

 

Oceania:

EMC: AS/NZS 3548/CISPR22 Class B

 

 

 

 

Japan:

EMI: VCCI Class A

 

 

 

 

Reliability

Product

Mechanism

12,000,000 passes (6,000,000 carriage returns)

 

lifetime:

Print head

1,600,000,000 shots/nozzle

 

 

 

(Shots are the numbers of pulses energized for the print

 

 

 

head.)

 

 

Autocutter

Plain paper, special fine paper 350,000 cuts

 

 

 

Special matte paper, plain borderless label paper

 

 

 

200,000 cuts

 

 

ASF

200,000 sheets

 

 

 

(The end of product lifetime is when the printer reaches

 

 

 

the start of the wear-out failure period.)

 

 

MTBF

180,000 hours (Failure is defined as a random failure occurring during the random

 

failure period.)

 

 

 

 

MCBF

30,000,000 passes

 

 

This is an average failure interval based on failures relating to wearout and random

 

failures up to the life of 12,000,000 passes.

 

 

 

Temperature and humidity

Printing:

10 to 35ºC, 20 to 80% RH no condensation

 

Storage:

Packaged for shipping 20 to 60ºC, 5 to 85% RH no condensation

 

 

 

(Ink not loaded)

 

 

 

(within 120 hours at 20ºC or 60ºC)

 

 

Ink loaded 20 to 40ºC, 20 to 85% RH

Absolute maximum rated

70ºC (This temperature must NOT be exceeded whenever it is operating or in

temperature

storage.)

 

 

 

 

 

Pressure (elevation)

Printing:

775 to 1,050 hPa (corresponding to 0 to 2,000 m above sea level)

 

Operating:

700 to 1,060 hPa (corresponding to 0 to 2,500 m above sea level)

 

 

 

 

Rev. C

Product Specifications of the TM-C100 A-1

Page 47
Image 47
Epson manual Product Specifications of the TM-C100