Eject sensor (E)
This sensor is located in the feeder paper path. It detects whether a document is properly ejected
and stored in a pocket.
Main pocket nearly full sensor (F)
This sensor is located in the Main pocket. It detects whether documents stored in the pocket need
to be removed.
•The sensor detects the nearly full status when the thickness of the documents in the
Main pocket exceeds the specified value (80 or more of documents whose thickness is
0.13 mm without folds, wrinkles, or roughness).
•To prevent paper jams, use the scanner in the driver mode that stops continuous processing when a
Sub pocket nearly full sensor (G) (except for the one pocket model)
This sensor is located in the Sub pocket. It detects whether documents stored in the pocket need
to be removed.
•The sensor detects the nearly full status when the thickness of the documents in the Sub
pocket exceeds the specified value (40 or more of documents whose thickness is 0.13
mm without folds, wrinkles, or roughness).
•To prevent paper jams, use the scanner in the driver mode that stops continuous pro- cessing when a
Cover Open Sensors
Scanner cover open sensor (H)
This sensor detects the opening/closing of the scanner cover. The scanner automatically goes offline when the cover is opened. It goes back online when the scanner cover is closed.
Franker cover open sensor (I)
This sensor detects the opening/closing of the franker cover. The scanner automatically goes offline when the cover is opened. It goes back online when the franker cover is closed.
24