LBI-38965

PHYSICAL DESCRIPTION AND COMPATIBILITY

The BCU/CAL is based on a VMEbus computing platform with the following components:

CPU

Technico TVME 147 single-board computer based on a 68030 microprocessor

Supports BCU/CAL application processing

Interfaces to hard disk, floppy disk, and tape drive via an on-board small computer systems interface (SCSI) with a connector on the transition module

Interfaces to the console terminal via an RS-232 serial port with a connector on the transition module

Network physical connection is 802.3 Ethernet, 10 BASE-15 (Thick Wire). A MAU may be used for connection to a Thin Wire (coaxial) network

Internal Drives

Hard Disk: 3½" 1.2 GB

Provides configuration parameter storage

Provides call detail record (CDR) storage

Provides raw activity record (RAR) buffering/storage

Floppy Disk: 3½" 1.44 MB

Used for application program updates Tape: 3½" 4/8 GB 4mm DAT

Provides call detail record (CDR) file archival storage

Provides general purpose file interchange with UNIX

UNIX Tar format, 512-byte tape block size, no data compression Communications Module

Formation WANServer fv5310

Interfaces the BCU/CAL via high-speed high-level data link control (HDLC) link to the Central Activity Module (CAM) in the Integrated Multisite and Console Controller (IMC)

System Manager Interface (CAL only)

One or Two Emulex Performance Series P2516-SLTL Terminal Servers

Communicates with the BCU/CAL over the network and with the System Manager over RS-232

Converts between Transmission Control Protocol (TCP) sockets and asynchronous serial protocol

10