LBI-39128

OPERATION

 

 

 

 

Table 7 - PMU Option Parameters

 

 

 

 

 

 

 

 

 

PARAMETER

SITE CONTROLLER

SYSTEM MANAGER

 

 

PMU

DESCRIPTION

COMPUTER

SITE DATABASE

 

 

ACTIVE

 

PERSONALITY PROMS

 

 

CONFIGURATION

 

 

 

 

 

 

Bit map parameter set that

PMU Enable

 

 

 

 

enables the PMU option on

(Channel Data screen)

 

 

 

 

a per-channel basis

Must be enabled here

 

 

 

 

(must also be enabled

 

 

 

 

(set to Y for enabled).

 

 

 

 

on a site-wide basis).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single bit parameter that

Power Monitor Unit

Power Monitor Unit

 

 

 

enables the PMU option on

(PMU screen)

Enabled

 

 

 

a site-wide basis

Must be set to On

(Site/Device Site Test

 

 

 

(must also be enabled

Parameters screen)

 

 

 

(without System Manager).

 

 

 

on a per-channel basis).

 

 

 

 

Should be set to On

Can be enabled here.

 

 

 

 

 

 

 

 

(w/wo System Manager).

(set to Y for enabled)

 

 

 

 

 

 

 

 

 

Single bit parameter that

PMU Model

 

 

 

 

identifies the PMU model.

(PMU screen)

 

 

 

 

 

Must be set to New-8860.

 

 

 

 

 

 

 

 

 

Single parameter that

PMU Power Levels

PMU Power Level

 

Lower Alarm Limit

sets the lower power limit

(PMU screen)

(Site/Device Site Test

(Analog Input Channel

(in watts) for transmitter

Must be set here

Parameters screen)

 

 

screen)

output power.

 

 

 

 

(without System Manager).

Can be re-configured here.

 

May temporarily be

 

 

 

Should be set here

Enter number from 0 to

configured here. Enter

 

(w/wo System Manager).

255. First non-zero level

number from 0.0 to 1000.

 

(Enter number from 0 to

applies to all channels.

Different limits can be

 

255. First non-zero level

 

configured for different

 

applies to all channels.)

 

 

 

channels.

 

 

 

 

Single parameters that

 

 

Other Pwr. Alarm Limits

define the following limits:

 

 

(Analog Input Channel

upper alarm limit for

 

 

 

 

screen)

transmitter output power

 

 

Can be re-configured here.

lower alarm limit for

 

 

Enter number from 0.0 to

antenna input power.

 

 

1000. Different limits can

upper power limit for

 

 

be configured for different

 

 

 

channels/antennas.

antenna input power.

 

 

 

 

 

 

 

 

 

 

 

 

 

Single parameters that

 

 

 

SWR Alarm Limits

define the upper and lower

 

 

(Analog Pseudo Channel

SWR limits for the

 

 

 

 

screen)

antenna input.

 

 

Can be re-configured here.

 

 

 

 

 

 

Enter number from 0.00 to

 

 

 

9.99. Different limits can be

 

 

 

configured for different

 

 

 

 

 

antennas.

 

 

 

 

 

Antenna Mapping defines

 

 

 

Antenna Channel

which antenna is used by

 

 

(Analog Input Channel

each transmitter channel.

 

 

 

 

screen)

 

 

 

 

 

See text.

 

 

 

 

 

 

 

 

 

 

 

 

26

Page 26
Image 26
Ericsson LBI-39128 manual Operation

LBI-39128 specifications

Ericsson LBI-39128 is a comprehensive communication solution designed to meet the ever-evolving demands of modern telecommunications. It is renowned for its ability to enhance network performance while providing a robust framework for various communication technologies. This product primarily targets service providers, enabling them to maximize their operational efficiency and improve service delivery.

One of the key features of the LBI-39128 is its versatility in supporting multiple generation technologies, including 2G, 3G, LTE, and even 5G. This ensures that service providers can seamlessly integrate their existing infrastructure and gradually evolve towards more advanced network capabilities without the need for a complete overhaul. The product caters to a wide array of deployment scenarios, from urban environments with high user density to rural areas requiring expansive coverage.

In terms of network performance, the LBI-39128 excels with its advanced radio technologies. It employs Massive MIMO (Multiple Input Multiple Output) and beamforming techniques, which significantly enhance spectral efficiency and improve user experience. With multiple antennas transmitting and receiving signals simultaneously, users benefit from increased throughput and reduced latency, essential for applications such as video streaming and real-time communications.

Another critical characteristic of the Ericsson LBI-39128 is its focus on energy efficiency. The product integrates intelligent power management systems that optimize energy consumption, thereby reducing operational costs for service providers. This aligns with the growing emphasis on sustainable practices within the telecommunications industry.

Moreover, the LBI-39128 features advanced management and automation capabilities. Its network function virtualization (NFV) support enables operators to deploy virtualized network functions efficiently, allowing for dynamic scaling and resource allocation based on real-time demand. This agility is crucial for handling varying loads and enhancing the overall resilience of the network.

Security is also a primary consideration in the design of the LBI-39128. It incorporates robust encryption methods and secure access protocols to protect sensitive data and ensure the integrity of communication channels. This is particularly important in an age where cyber threats are becoming increasingly prevalent.

In summary, the Ericsson LBI-39128 is a state-of-the-art telecommunications solution that stands out due to its support for multiple technologies, advanced radio capabilities, energy efficiency, automated management, and robust security features. Its design reflects the needs of contemporary service providers, allowing them to build and sustain high-performance networks that meet the demands of future communications.