MAINTENANCE |
REPORT SELECTION MENU
1.RETURN TO OPERATION SELECT MENU
2.ALARM REPORT
3.ALARM HISTORY
4.CURRENT STATUS
5.CHANNEL MONITOR
6.
7.CHANNEL DUMP
ENTER SELECTION:
Figure 23 - Report Selection Menu
|
|
| ALARM HISTORY REPORT |
| |||
SITE - NOT PROGRAMMED |
|
|
|
|
| ||
TIME | 2:50pm | DATE 1/18 |
|
|
|
|
|
UNIT | CHANNEL | DESCRIPTION | VALUE |
| TYPE(S) | TIME | DATE |
AI06 | AI006 | TX06 | 29.4 | Watts F | L | 2:49pm | 1/18 |
AI25 | AI025 | ANT01 | 0.0 | Watts F | L | 2:49pm | 1/18 |
Press any | key to continue (Esc to abort) |
|
| ||
|
|
|
| ||
|
| Figure 24 - Alarm History Report Screen |
| ||
|
|
|
|
| |
10:32am | 2/03 | CHANNEL M O N I T O R | REPORT |
| |
Esc aborts |
|
|
| Timeout in 15 min | |
UNIT CHNL | DESCRIPTION | ALARMS | VALUE | UNITS ONTIME | UPLIMIT LOLIMIT |
AI01 AI001 TXO1 | 101.3*WATTS |
| 50.0 | 125.0 |
Selected |
|
| |
Calculated Power or | |||
Analog Input Channel or |
| ||
| Calculated SWR | ||
Analog Pseudo Channel |
| ||
|
| ||
|
|
|
Figure 25 - Channel Monitor Screen
The second part of the screen is a real time display of the calculated value. It may take a while to get used to the unlabeled format. Only one value is usually shown at a time. A number with one decimal place is a power calculation. A number with two decimal places is an SWR calculation. A number from 15 to 1 is the time remaining until screen times out.
Calculations are made every 250 milliseconds during the time the associated transmitter is keyed. This includes the first 750 milliseconds after a transmitter is keyed, when
alarm conditions are not reported to the Site Controller computer. Therefore, you may briefly see a value that exceeds the alarm limit and notice that no alarm is sent to the Site Controller computer.
Connect the terminal to the PMU and access the PMU as described under the PMU Programming heading in the Installation section of this manual. Then use the following procedure to access the Channel Monitor screen:
31