MAINTENANCE

LBI-39128

REPORT SELECTION MENU

1.RETURN TO OPERATION SELECT MENU

2.ALARM REPORT

3.ALARM HISTORY

4.CURRENT STATUS

5.CHANNEL MONITOR

6.CHANNEL-ON TIMERS

7.CHANNEL DUMP

ENTER SELECTION:

Figure 23 - Report Selection Menu

 

 

 

ALARM HISTORY REPORT

 

SITE - NOT PROGRAMMED

 

 

 

 

 

TIME

2:50pm

DATE 1/18

 

 

 

 

 

UNIT

CHANNEL

DESCRIPTION

VALUE

 

TYPE(S)

TIME

DATE

AI06

AI006

TX06

29.4

Watts F

L

2:49pm

1/18

AI25

AI025

ANT01

0.0

Watts F

L

2:49pm

1/18

Press any

key to continue (Esc to abort)

 

 

 

 

 

 

 

 

Figure 24 - Alarm History Report Screen

 

 

 

 

 

 

10:32am

2/03

CHANNEL M O N I T O R

REPORT

 

Esc aborts

 

 

 

Timeout in 15 min

UNIT CHNL

DESCRIPTION

ALARMS

VALUE

UNITS ONTIME

UPLIMIT LOLIMIT

AI01 AI001 TXO1

101.3*WATTS

 

50.0

125.0

Selected

 

 

Calculated Power or

Analog Input Channel or

 

 

Calculated SWR

Analog Pseudo Channel

 

 

 

 

 

 

Figure 25 - Channel Monitor Screen

The second part of the screen is a real time display of the calculated value. It may take a while to get used to the unlabeled format. Only one value is usually shown at a time. A number with one decimal place is a power calculation. A number with two decimal places is an SWR calculation. A number from 15 to 1 is the time remaining until screen times out.

Calculations are made every 250 milliseconds during the time the associated transmitter is keyed. This includes the first 750 milliseconds after a transmitter is keyed, when

alarm conditions are not reported to the Site Controller computer. Therefore, you may briefly see a value that exceeds the alarm limit and notice that no alarm is sent to the Site Controller computer.

Connect the terminal to the PMU and access the PMU as described under the PMU Programming heading in the Installation section of this manual. Then use the following procedure to access the Channel Monitor screen: