ZEUS Technical Manual | Detailed hardware description |
|
|
Serial COM ports
There are seven serial communications ports available on the ZEUS. Three are provided by the PXA270 and are used for the optional wireless modem, GPS and IEEE802.15.4 / ZigBee ports.
There are four additional
Port | Address | IRQ | FIFO depth | Signals |
RX / TX | ||||
COM1 | 0x10000000 – | GPIO9 | 16/16 | RS232: Rx, Tx, CTS, RTS, RI, |
| 0x1000000F |
|
| DSR, DCD, DTR |
COM2 | 0x10800000 – | GPIO10 | 16/16 | RS232: Rx, Tx, CTS, RTS, RI, |
| 0x1080000F |
|
| DSR, DCD, DTR |
COM3 | 0x11000000 – | GPIO12 | 16/16 | RS232: Rx, Tx, CTS, RTS, RI, |
| 0x1100000F |
|
| DSR, DCD, DTR |
|
|
|
| or |
|
|
|
| RS422/485: Rx, Tx |
COM4 | 0x11800010 – | GPIO11 | 16/16 | RS422/RS485: Rx, Tx |
| 0x1180001F |
|
|
|
|
|
|
|
|
COM1/2 – RS232 interface
Supported on Channel A and B of the external Quad UART, the ports are buffered to RS232 levels with ±15kV ESD protection, and support full handshaking and modem control signals. The maximum baud rate is 921.6 Kbaud. COM1 and COM2 ports can be accessed using DB9 connectors J11 and J15, respectively. For pin assignment and connector details, see J11 – Serial port – COM1 on page 83 and J15 – Serial port – COM2 on page 86.
A factory fit option configures COM1 as TTL Level signals to interface to certain specialized modems. Please contact Eurotech Technical Support (see page 97) for details.
© 2007 Eurotech Ltd Issue D | 53 |