ZEUS Technical Manual | Connectors, LEDs and jumpers |
|
|
JP5 & JP6 – CAN bus termination
Connector:
| JP5 |
|
| JP6 | JP5 | JP6 | ||
Pin | Signal name |
| Pin | Signal name | ||||
|
|
|
|
|
|
|
|
|
1 | CANH | 1 | Centre tap | 2 | 1 | 1 | 2 | |
|
|
|
|
| ||||
2 | Centre Tap | 2 | CANL |
|
|
|
| |
|
|
|
|
|
|
|
|
|
JP5 & JP6 | Description |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
| 62Ω Termination connected |
|
|
|
|
62Ω Termination disconnected (default)
Only insert jumpers JP5 and JP6 if the ZEUS is at the end of the network.