2.5 ALARM IN- / OUT INSTALLATION

Alarm- in- and outputs are connected to the screwless terminal at backside of the camera. For Details to input/output circuit refer to Attachment A.

2.5.1 Terminal pin assignment:

Contact

 

Description

 

 

1

Alarm IN 1 + (max 50 V DC)

2

 

Alarm IN 1 -

3

Alarm IN 2 + (max 50 V DC)

4

 

Alarm IN 2 -

5

Relay COM

(max. 24 V DC / 1 A)

6

Relay N.C.

(max. 24 V DC / 1 A)

7

Relay N.O.

(max. 24 V DC / 1 A)

8

 

RS-485+

9

 

RS-485-

10

 

+ 3,3 VDC Output

11

 

GND

Both alarm inputs are opto-coupler inputs and require DC Voltage 3~50 VDC for activation.

2.5.2 Alarm Inputs

Following connection methods are possible:

A) Installation of dry N.O. contact with camera power source

Alarm In 1

 

 

 

Alarm In 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12 of 59

Page 12
Image 12
EverFocus EAN-1350 manual Alarm IN- / OUT Installation, Terminal pin assignment, Alarm Inputs, Contact Description