Normally Open
(N.O.)

MENU

(c) Alarm in and alarm reset

There is 1 alarm sensor in for 1 channel and 1 alarm reset in, the alarm input can be set to Normally Open or Normally Closed by user.

 

 

ALARM

 

 

CIRCUIT

SENSOR 1

 

 

8

2

1

15

 

9

ALARM RESET

 

 

Alarm in

There is one alarm input. Please connect the alarm input in the same sequence as the camera input BNC.

When alarm signal comes in, the Digital Video Recorder will do the following:

1.Display Alarm Message

2.Turn on the buzzer if the buzzer setting is on.

The ALARM in can be selected as normally open input or normally closed input:

: If the alarm input is selected as Normally Open input, then the

input is opened normally, and shorted to the ground means an alarm happens. Normally Close : If the alarm input is selected as Normally Close input, then the

(N.C.) input is shored to the ground normally, and opened input means an alarm happens.

24