terminal resistance settings. All of the settings should be confirmed before the dome is installed. The control-related setting that is address, communication protocol and transmission speed have to be set consistently with the control device such as a keyboard or a DVR.

Notice: Please make sure the power is off before setting, and restart the EPTZ3100/EPTZ3100I to enable a new value after changing.

2.3.1. Address Setting

The address code of the EPTZ3100/EPTZ3100I should be set to correspond properly with a control device to control multiple dome cameras. The address codes are made up by the dip switch on the camera main body. The 8 bits dip switch indicates the binary coded of the address, and there are 256 addresses can be selected (0 ~ 255). It also means that there are up to 256 dome cameras that can cascade on the RS-485 bus. The dip switch setting and the indicated address are represented in the following diagram.

Note: The factory default address is 1.

Notice: Please make sure the power is off before setting, and restart the EPTZ3100/EPTZ3100I to enable a new value after changing.

16

Page 16
Image 16
EverFocus EPTZ3100I user manual Address Setting