EZN850
4.7.4 Serial Communication
RS485 Setting
Camera ID: This entry is used to assign camera own ID code.
Baud Rate: This field is to set the speed at which is used to transmit instruction or information through the RS485 port on the camera. There are six different speeds, 2400/4800/9600/19200/38400/57600. The default setting from the factory is 9600.
Protocol: Select protocol from EverFocus and
Data Bit: This field is the data bit at which you will be transferring. There are two
settings for this option: 8 or 7. The default is set to 8.
Stop Bit: This field is to set the stop bit for the RS485 connection. There are two different stop bits, 1 or 2. The default is set to 1.
Parity: This field is to select the parity level at which you will be connected. You can choose between None, Odd, or Even parity levels. Default is set to none.
53