1. TOTALLY INOPERATIVE

1. TOTALLY INOPERATIVE

YES

POWER

NO

PRESENT AT

 

RECEPTACLE

 

 

 

 

 

 

 

CHECK OR LOOSE CONNECTION

OR BROKEN WIRE INSIDE UNIT

IS LINE

VOLTAGE

NOWITHIN ¦ 10% OF

NAMEPLATE

VOLTAGE?

YES

1.CHECK FOR SHORT CIRCUIT IN WIRING INSIDE UNIT.

2.CHECK COMPONENTS FOR SHORT CIRCUIT OR GROUNDED WIRING.

IS

LINE VOLTAGE LOW

HIGH OR

LOW

 

IS

YES

SUPPLY FUSE

 

BLOWN (OR C/B

 

TRIPPED)?

 

NO

 

CHECK FOR LOOSE CONNECTION

 

OR BROKEN WIRE IN SUPPLY

 

WIRING TO UNIT.

IS

YESFUSE OR C/B

SIZE PROPER

NO

REPLACE WITH CORRECT

SIZE DEVICE.

HIGH

INSTALL BUCKING TRANSFORMER TO REDUCE LINE VOLTAGE.

1.REMOVE ALL OTHER EQUIPMENT FROM ICEMAKER CIRCUIT

2.INSTALL NEW DEDICATED CIRCUIT FOR ICEMAKER.

IS

OTHER EQUIP.

YES ON SAME

CIRCUIT

NO

1.CHECK FOR LOOSE OR CORRODED CONNECTION IN SUPPLY WIRING.

2.CHECK SUPPLY WIRING FOR UNDER- SIZED WIRE, AND REPLACE.

3.INSTALL BOOSTING TRANSFORMER TO RAISE LINE VOLTAGE.