2.D FROZEN EVAPORATOR

1.SHUTOFF ICE MAKER AND THAW EVAPORATOR.

2.START ICE MAKER.

IS

AMBIENT ABOVE NO 60°F?

1.ARRANGE TO MAINTAIN MINIMUM 60°AMBIENT.

2.CONDUCT FACTORY REGARDING SPECIAL APPLICATION.

YES

IS

VOLTAGE WITHIN NO

±10%?

YES

DISCONNECT PROBE WIRE FROM

CONDUCTIVITY CONTROL.

ARE ALL

TIMING FUNCTIONS

ACCURATE TO SETTINGS

±10%?

YES

HOT

GAS OPERATION NO

O.K.?

YES

 

WATER

NO

DUMP

 

O.K.?

 

YES

 

CHECK VOLTAGE ITEMS IN 1.

NO

1. CHECK TIMER MOTOR.

2.CHECK CONDUCTIVITY CONTROL.

1.CHECK ADJUSTMENT OF TIMER CAM #2. (HOT GAS)

2.CHECK TIMER SWITCH #2.

3.CHECK HOT GAS SOLENOID.

1.CHECK ADJUSTMENT OF TIMER CAM #4 (WATER DUMP)

2.CHECK TIMER SWITCH #4

3.CHECK DUMP SOLENOID

DOES

ICE HARVESTNO NORMALLY?

YES