Everpure 80, SID650A manual Beverage System Problem

Models: 80 SID650A

1 41
Download 41 pages 50.53 Kb
Page 37
Image 37
4. BEVERAGE SYSTEM PROBLEM

4. BEVERAGE SYSTEM PROBLEM

IS

ONE OR MORE

FAUCETSYES INOPERATIVE?

NO

IS

BEVERAGENO COLD?

YES

IS

BEVERAGE PROPERLYNO CARBONATED?

1.CHECK WIRING CONNECTIONS TO INOPERATIVE FAUCETS.

2.REPLACE INOPERATIVE FAUCETS.

3.CHECK WIRING CONNECTIONS FROM 24 V. TRANSFORMER.

4.CHECK 24 V. TRANSFORMER.

1.CHECK FOR ICE ON COLD PLATE. (--BC MODELS)

2.CHECK REMOTE COOLING SYSTEM. (--B MODELS)

1.CHECK CO2 PRESSURE.

2.CHECK CARBONATOR.

YES

IS

BEVERAGE TOOYES SWEET?

NO

IS

BEVERAGE TOOYES WATERY?

1.CHECK WATER SUPPLY PRESSURE.

2.CHECK SUPPLY FILTER.

3.CHECK CARBONATOR.

4.CHECK FAUCET BRIX.

1.CHECK IF SYRUP BIB IS EMPTY.

2.CHECK CO2 PRESSURE.

3.CHECK FAUCET BRIX.

NO

DONE

33

90846

Page 37
Image 37
Everpure 80, SID650A manual Beverage System Problem