2.D (CON’T)

YESNO

1. CHECK ADJUSTMENT OF TIMER CAM #3. (HARVEST MOTOR)

2. CHECK TIMER SWITCH #3.

3. CHECK HARVEST MOTOR CAPACITOR.

4. CHECK HARVEST MOTOR.

REPLACE PROBE WIRE ON

CONDUCTIVITY CONTROL

DURING HARVEST CYCLE.

DOES

TIMER RETURN NO

HOME?

YES

WAIT ONE FULL FREEZING

CYCLE (APPROX. 6-10 MIN.)

1.CHECK ADJUSTMENT OF TIMER CAM #1. (TIMER HOME)

2.CHECK TIMER SWITCH #1.

DOES

HARVESTNO

INITIATE?

YES

1.CHECK PROBE WIRING FOR SHORTED CONNECTION.

2.CHECK CONDUCTIVITY CONTROL.

DOES

ICE HARVESTNO NORMALLY?

1.REPEAT PREVIOUS CHECK OF OPERATION OF HARVEST COMPONENTS IN 2.D

2.ADJUST ICE THICKNESS PROBE ONLY

AFTER ALL OTHER FACTORS HAVE BEEN CHECKED THOROUGHLY.

YES

DONE