Everpure SID650A, 80 manual Line Voltage, Contactor

Models: 80 SID650A

1 41
Download 41 pages 50.53 Kb
Page 30
Image 30
LINE VOLTAGE

2.B COMPRESSOR INOPERATIVE

YES

IS

THERMAL

PROTECTOR

OPEN?

YES

IS

YES COMPRESSOR BODY COLD?

REPLACE

THERMAL

PROTECTOR.

YES

IS

 

 

LINE VOLTAGE

NO

CHECK VOLTAGE PROBLEMS IN 1.

WITHIN ¦ 10%

 

OF NAMEPLATE

 

 

VOLTAGE

 

 

 

IS

 

NO

CONTACTOR

YES

 

PULLED

 

 

IN

 

 

NO

 

 

 

 

 

 

 

 

 

 

1.

CHECK FOR LOOSE OR BROKEN

 

 

 

 

WIRING CONNECTION IN COMPRESSOR

NO

 

 

POWER CIRCUIT.

 

2.

CHECK CONTACTOR.

 

 

 

 

 

 

3.

CHECK STARTING RELAY.

 

 

 

4.

CHECK CAPACITOR(S).

 

 

 

5.

CHECK COMPRESSOR MOTOR.

 

 

 

 

 

 

 

 

 

 

 

 

IS

120V.

PRESENT AT

CONTACTOR NO COIL

TERMINAL?

REPLACE CONTACTOR.

1.CHECK FOR LOOSE OR BROKEN WIRING CONNECTION IN CONTROL CIRCUIT.

2.GO TO 2.A

90846

26