Maintenance

Voltage

Percent

Maximum

Charging

Reading

Charge

Charger

Interval

 

 

Settings

 

12.0–12.2

25–50%

14.4 volts/4

2 Hours

 

 

amps

 

11.7–12.0

0–25%

14.4 volts/4

3 Hours

 

 

amps

 

11.7 or less

0%

14.4 volts/2

6 Hours or

 

 

amps

More

Important: For Kohler EFI units: Unplug the harness from the ECU before performing any welding on the equipment.

Recommended Jump

Starting Procedure

Service Interval: As required

1.Check the weak battery for terminal corrosion (white, green, or blue “snow”), it must be cleaned off prior to jump starting. Clean and tighten connections as necessary.

CAUTION

Corrosion or loose connections can cause unwanted electrical voltage spikes at anytime during the jump starting procedure.

Do Not attempt to jump start with loose or corroded battery terminals or damage to the engine or EFI may occur.

CAUTION

Connecting the jumper cables incorrectly (wrong polarity) can immediately damage the EFI system.

Be certain of battery terminal polarity and jumper cable polarity when hooking up batteries.

Note: The following instructions are adapted from the SAE J1494 Rev. Dec. 2001 – Battery Booster Cables – Surface Vehicle Recommended Practice (SAE – Society of Automotive Engineers).

WARNING

Batteries contain acid and produce explosive gases.

Shield the eyes and face from the batteries at all times.

Do Not lean over the batteries.

Note: Be sure the vent caps are tight and level. Place a damp cloth, if available, over any vent caps on both batteries. Be sure the vehicles do not touch and that both electrical systems are off and at the same rated system voltage. These instructions are for negative ground systems only.

3.Connect the positive (+) cable to the positive (+) terminal of the discharged battery that is wired to the starter or solenoid as shown in Figure 16.

DANGER

Jump starting a weak battery that is cracked, frozen, has low electrolyte level, or an open/shorted battery cell, can cause an explosion resulting in serious personal injury.

Do Not jump start a weak battery if these conditions exist.

2.Make sure the booster is a good and fully charged lead acid battery at 12.6 volts or greater. Use properly sized jumper cables (4 to 6 AWG) with short lengths to reduce voltage drop between systems. Make sure the cables are color coded or labeled for the correct polarity.

Figure 16

1.Positive (+) cable on discharged battery

2.Positive (+) cable on booster battery

3.Negative (–) cable on the booster battery

4.Negative (–) cable on the engine block

5.Booster battery

6.Discharged battery

7.Engine block

28

Page 28
Image 28
Exmark 4500-759 Rev A Recommended Jump Starting Procedure, Do Not jump start a weak battery if these conditions exist

4500-759 Rev A specifications

The Exmark 4500-759 Rev A represents an innovative leap in turf management equipment, designed to enhance the efficiency and effectiveness of landscaping professionals. As a leading name in the lawn care industry, Exmark has equipped this model with state-of-the-art technologies and features that cater to both commercial and residential users.

One of the standout characteristics of the Exmark 4500-759 Rev A is its robust engine performance. Powered by a high-efficiency engine, it delivers consistent power and torque, allowing for seamless operation across diverse terrains. This engine is complemented by advanced cooling systems, ensuring optimal temperature management during extended use, which ultimately prolongs the equipment's lifespan.

The cutting system on the 4500-759 Rev A is another highlight, featuring Exmark’s patented cutting deck design. The advanced blade and deck configuration promotes superior grass dispersion and minimizes clumping, resulting in a polished finish that landscapers strive to achieve. The adjustable cutting height feature allows users to tailor the lawn height to their preference, making it versatile for various types of grass and seasonal conditions.

Operator comfort and ease of use are paramount in the design of the Exmark 4500-759 Rev A. The ergonomically designed seat and user-friendly controls provide a smooth driving experience. The intuitive dashboard offers easy access to critical information about the mower’s operation, ensuring that operators can focus on the task at hand without any distractions.

Additionally, this model incorporates innovative technology with its integrated GPS tracking system, which enhances efficiency by allowing users to monitor location and performance remotely. This feature not only aids in job tracking but also supports maintenance scheduling, optimizing service intervals and reducing downtime.

Furthermore, the Exmark 4500-759 Rev A is built with durability in mind. The heavy-duty frame and reinforced components withstand rigorous use, ensuring long-lasting performance in demanding environments. The model's versatility enables it to adapt for various landscaping tasks, from mowing to mulching, making it a valuable tool for professionals.

In conclusion, the Exmark 4500-759 Rev A is a powerful and versatile mower equipped with advanced technologies that simplify lawn care while maximizing results. Its combination of performance, comfort, and durability positions it as an essential choice for those in the landscaping industry, empowering users to achieve their desired outcomes with confidence.