Extron electronic CTR 8 manual Application Diagrams, Application with “Show Me” Cables

Models: CTR 8

1 21
Download 21 pages 49.15 Kb
Page 9
Image 9
Application Diagrams

CRemote RS-232 port — Connect the serial port of a control computer to this female captive screw connector as shown below.

Transmit (Tx)

Receive (Rx)

Ground (G)

Tx Rx G

RS-232

Figure 5. RS-232 Input Wiring

The protocol for the RS-232 port is 9600 baud, 8 data bits, 1 stop bit, no parity.

DCOM switcher port — Connect an Extron switcher to this female captive screw

connector as shown below. Only connect the Tx and G pins of the CTR 8.

CTR 8

Switcher

COM

REMOTE

Tx G

Tx Rx G

Transmit (Tx)

Ground (G)

Figure 6. COM Input Wiring

The protocol for the COM port is 9600 (default), 19200, 38400, or 57600 baud; 8 data bits, 1 stop bit, no parity.

Application Diagrams

Application with “Show Me” Cables

Contact Closure and Tally

Power

Supply

Extron

CTR 8

Eight Input Contact

Closure to RS-232

Control Module

POWER OUT

 

CONTA

CT IN / TA

LLY OUT

 

 

COM

 

1.0A

 

 

 

 

 

 

 

 

 

 

 

MAX

 

 

 

 

 

 

 

 

 

 

RS-232

12V

C G 1 T +V C G 2 T +V C G 3 T +V C G 4 T +V

 

Tx G

 

 

 

 

 

 

REMOTE

POWER IN

5

6

7

8

 

RS-232

 

1.0A

 

 

 

 

 

 

 

 

 

 

 

MAX

 

 

 

 

 

 

 

 

 

 

 

 

 

C G T +V C G T +V C G T +V C G T +V

 

Tx Rx G

 

 

100-240V ~ 50/60 Hz

 

 

 

INPUTS

 

 

IN1606

OUTPUTS

 

 

 

 

AUDIO INPUTS

 

 

 

OUTPUTS

 

REMOTE

Extron

-- A MAX

1

 

3

 

5

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONFIGURABLE

 

 

 

 

 

 

 

L

1

R

L

3

R

L

5

R

 

1

1

2

 

LAN

IN1606

 

2

4

HDMI

6

HDMI

 

B

HDMI

 

 

 

 

 

 

 

 

 

+48V

MIC/LINE

LVARIABLER

 

 

 

 

 

L

2

R

L

4

R

L

6

R

2

RESET

RS-232

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+48V

 

 

 

 

 

Scaling Presentation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tx Rx G

Switcher

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HDMI Video and

Embedded Audio

Ethernet

TCP/IP

Network

Contact Closure and Tally

VGA/HDMI “Show Me” Cables

Flat Panel Display

RS-232

EthernetApplication with “Show Me” Cables Extron

IPL 250

IP Link Control

Processor

 

 

COM1

COM 2

 

IR

 

 

RELAY

 

 

Tx Rx

RTS CTS

Tx Rx

1

2

1

2

 

 

 

 

 

 

 

 

 

 

POWER

LAN

 

 

S

G S

G

 

 

12V

 

 

 

 

 

 

 

500mA

 

INPUT

COM 3

 

IR

 

 

RELAY

MAX

1 2

3 4

Tx Rx

3

4

3

4

S G S G

CTR 8 • Panels and Cabling

4