Extron electronic manual IPL T CR48 Communication and Control, N Zero 0 clears broadcast mode

Models: IPL T CR48

1 66
Download 66 pages 29.57 Kb
Page 43
Image 43

X3( = Event data to write

X4# = Input state: 0 = off; 1 = on

X4$ = Number of bytes to read

X4% = E-mail event number: Range = 1-64 (Max)

X4^ = E-mail recipient address: Maximum number of characters for a full e-mail address is 31 characters.

X4& = Name of e-mail file to be sent: first line of file is subject, the rest is the body of the e-mail.

NE-mail files must have the file extension .eml.

X4* = Event Status fields (8): event_type, event_state, event_paused, error_status, RcvBuff_startptr, RcvBuff_endptr, UsrBuff_startptr, UsrBuff_endptr

X4( = Default Name: Combination of model-name and last 3 pairs of MAC address (e.g., IPL-T-CR48-00-02-3D)

X5! = Direct access: 0 = direct access not in use; 1 = direct access in use

X5@ = Connection’s security level: 0 = not logged in, 1 = user, 2 = administrator

X5# = Timeout for data pass-through mode, after which event data can be inserted into the transmit buffer.

X5$ = ASCII digit(s) representing numeric value of data element read from event buffer; leading zeros are suppressed.

X6# = Pulse time in 20 ms per count. If parameter is missing or = 0, pulse length = default (25 counts = 500 ms), max (65536 counts)

X6$ = Time in seconds to keep sending the broadcast message (0-255, default 10)

NZero (0) clears broadcast mode.

Copyright information

]© COPYRIGHT 2003, EXTRON ELECTRONICS IPL T CR48,

Vx.xx]

Mon, 17 Feb 2003 11:27:33]

The copyright message is displayed upon connecting to

IP Link® product via TCP/IP or Telnet. Vx.xx is the firmware version number. The current date and time is displayed. This is followed by a Password prompt.

IPL T CR48 • Communication and Control 4-13

Page 43
Image 43
Extron electronic manual IPL T CR48 Communication and Control, N E-mail files must have the file extension .eml