Extron electronic IPL T CR48 Communication and Control, cont’d, Command, ASCII Telnet, Response

Models: IPL T CR48

1 66
Download 66 pages 29.57 Kb
Page 46
Image 46
4-16 IPL T CR48 • Communication and Control

4-16 IPL T CR48 • Communication and Control

Command

ASCII (Telnet)

URL Encoded (Web)

Response

 

 

 

 

Query factory firmware

3Q

3Q

X1! (plus web ver.-desc-UL

version

 

 

date/time)]

Query updated firmware

4Q

4Q

X1!(plus web ver.-desc-UL

version

date/time)]

 

 

NAn asterisk (*) placed after the version number indicates which version is currently running. A question mark (?) indicates that only the factory firmware version is loaded. A caret (^) after the version number indicates the firmware version that should be running, but a Mode 1 reset was executed. The default factory firmware version is loaded. An exclamation point (!) after the version number indicates corrupted firmware.

Request part number

N

N

60-544-05]

Request model number

1I

1I

IPL T CR48

Request model

2I

2I

Four contact input ports ,

description

 

 

Eight relay ports]

Request system memory

3I

3I

# bytes used out of #

usage

 

 

kbytes]

Request user memory

4I

4I

# bytes used out of #

usage

 

 

kbytes]

 

 

 

 

IP Setup Commandsz

 

 

 

Set Unit name

E X1@CN}

WX1@CN

Ipn • X1@]

Set Unit name to factory

E•CN}

W%20CN

Ipn • X4(]

default24

 

 

 

NX1! = Unit version number

X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and/or a minus sign/hyphen (-). X4( = Default Name: Combination of model-name and last 3 pairs of MAC address (e.g., IPL-T-CR48-00-02-3D)