Extron electronic manual IPL T CR48 Communication and Control

Models: IPL T CR48

1 66
Download 66 pages 29.57 Kb
Page 42
Image 42
Communication and Control

Communication and Control

X1! = Unit version number

X1@ = Name is a text string of up to 24 characters drawn from the alphabet (A-Z), digits (0-9), and/or a minus sign/hyphen (-). No blank or space characters are permitted as part of a name. No distinction is made between upper and lower case. The first character must be an alpha character. The last character can not be a minus sign/hyphen.

X1# = Set local date and time format (MM/DD/YY-HH:MM:SS, e.g., 06/21/02-10:54:00)

Read local date and time format (day of week, date month year HH:MM:SS, e.g., Thu, 20 Feb 2003 18:19:33)

X1$ = IP address (xxx.xxx.xxx.xxx); leading zeros in each of four fields are optional in setting values, and are suppressed in returned values.

X1% = Domain name (e.g., extron.com, icia.org)

X1* = Hardware (MAC) address (xx-xx-xx-xx-xx-xx)

X1( = Subnet mask (xxx.xxx.xxx.xxx); leading zeros in each of four fields are optional in setting values, and are suppressed in returned values.

X2@ = Status: 0 = working; 1 = fail

X2# = Priority status for receive timeout: 0 = priority set to Send Data String command parameters; 1 = priority set to Configure rcv timeout command parameters.

X3# = Password: maximum length of 12 characters and no special characters.

NUser password cannot be assigned if no administrator password exists and returns E14. If an admin password is cleared, then the user password is removed too.

X3$ = Daylight saving time: 0 = off/ignore; 1 = on (use in northern hemisphere)

X3% = Event number: range = 0 - 99 (Max.)

X3^ = Event buffer: 0 = receive; 1 = user (absolute); 2 = user (relative); 3

= NVRAM

X3& = Event buffer offset: range = 0 - MaxBufferSize

X3* = Event data size: b = bit; B = byte (8 bit); S = short (16 bit); L = long (32 bit)

NThis parameter is case sensitive.

4-12 IPL T CR48 • Communication and Control

Page 42
Image 42
Extron electronic manual IPL T CR48 Communication and Control