Extron electronic IPL T CR48 manual Communication and Control, cont’d, Event Control

Models: IPL T CR48

1 66
Download 66 pages 29.57 Kb
Page 52
Image 52
Event Control

4-22 IPL T CR48 • Communication and Control

Command

ASCII (Telnet)

URL Encoded (Web)

Response

 

 

 

 

Read mail server IP,

ECM}

WX1$%2CX1%CM

X1$,X1%]

domain name

 

 

 

 

 

 

 

Event Control

 

 

 

Read event buffer

EX3%,X3^,X3&,X3*E}

WX3%,X3^,X3&,X3*E

X%]

memory27

 

 

 

Read event status27

E X3%E}

1BWX3%E

<see X4*>]

Write event memory24 27

E X3%,X3^,X3&,X3(,X3*E}

WX3%,X3^,X3&,X3(,X3*E

EwrX3%,X3(]

Read string from event

E X3%,X3^,X3&,X4$FE}

WX3%,X3^,X3&,X4$FE

{string}]

memory

 

 

 

Write string to event

E{string}X3%,X3^,X3&FE}

WX3(%2AX3%,X3^,X3&FE

EwrX3%,{string}]

memory

 

 

 

Start Events24 27

E1AE}

W1AE

Ego]

 

 

 

 

NX% = On/off status: 0 = off/disable; 1 = on/enable X1$ = IP address

X1% = Domain name

X3% = Event number: range = 0 - 99 (Max.)

X3^ = Event buffer: 0 = receive; 1 = user (absolute); 2 = user (relative); 3 = NVRAM

X3& = Event buffer offset: range = 0 - MaxBufferSize

X3* = Event data size: b = bit; B = byte (8 bit); S = short (16 bit); L = long (32 bit). See Note on pg 4-12. X3( = Event data to write

X4$ = Number of bytes to read

X4* = Event Status fields